The pump is basically a jerk type with a plunger moving in a matched barrel, using two helical grooves machined in the plunger to control the end of injection by uncovering spill ports and causing the discharge pressure to drop rapidly, thus causing the needle valve in the injector to close.
Oil is supplied to the barrel via the spill ports and a suction valve. The suction valve, situated at the top of the barrel opens when the pressure in the barrel falls below the supply pump pressure; i.e. during downward stroke of plunger, while spill ports are covered by plunger.
Replaceable erosion plugs are fitted in the pump housing opposite the spill ports. The high pressure oil, spilling back, as the edge of the helix uncovers the spill ports at the end of injection, hit the plugs, which prevent damage to the pump casing